MoistureTesting
27
ForMoistureDetection,Measurement
andTesting in theFlooring Industry
• Detect if there is continuousmoisturemigration
toward the surface
• Test surface andmid-sectionof concrete slabs
• Reduce chances of excessmoisture inwood floors
and subfloors
• Identify potential for delamination in synthetic floors
TotalCheck
3 in 1Meter
#DI-2000
Offers scan and pinmoisturemodes as well as
a thermo-hygrometer that measures ambient
temperature and relative humidity (RH) and
calculates dew point and specific humidity (GPP).
Relative humidity is a crucial factor to consider
when installing a floor over a concrete subfloor.
The RH sensor of TotalCheck is removable and
conforms to the ASTM F-2170 standard to deter-
mine if concrete floors have dried adequately
before installing a floor covering.
PinMode:
•5%-60%MCwood scale
•Corrects for 69 individual wood species from5%-60%
•Corrects for temp. from0°-255°F
•0.1%-6% sheetrock scale
•0-100 numerical reference scale for non-wood buildingmaterials
ScanMode:
•0-300 numerical reference scale
Thermo-Hygrometer with RHSensor
•Measures temp. from -4°-158°F
•Measures RH from0-100%
•Calculates dew point
•Calculates specific humidity
General Features:
•Connector for external electrodes
•On-screen reading recall of up to
1400 stored readings
•Date and time stamp for each
stored reading
• Job groupings
• Infrared linking to PC or laptop
• Application software - generate
reports andmanage data
• Includes 9V battery, 1-year
warranty, carrying case
KitContents
Description
Cat.No.
Qty.
PCKit
DI.2050
1 ea.
TotalCheckMeter
DI.2000
1 ea.
Sleeves*
DI.2200.20 10 ea.
Humidity Probe** (sensor)
DI.2500.05 1 ea.
2-Pin Electrode
DI.2E
1 ea.
Humidity Probe Cable
DI.2500.RHC 1ea.
*Sleeves are sold20 per pack
** Probes are sold5 per pack
PCKit
•Download stored readings frommeter to PC
via infrared linking
• Export job data to Excel
•Customize printing options
• View readings and stats in the application
program
•Save and print individual or group job readings
•Customize job title
• View temperature in Fahrenheit or Celsius
• Append notes to each job
•Generate graphical histogram
Humidity Probe
CalibrationCheck Salt
Solutions 33%&75%
A simple, easy way to
check to insure that
probes arewithin
calibration tolerances.
#DI.SALT.33 #DI.SALT.75
In-Situ Probe for
ASTM-2170Moisture
Detection,Measurement
and Testing
RelativeHumidity Test
DI.4000.RH
Kit Contents
•RELATIVEHUMIDITY
Meter
• Ten 3 ” sleeves
DI.3200.20
•1Humidity probe
w/cableDI.2500.05
•Carry case
and INCLUDES:
•1Drill bit
DI.625.DRILL
•Wire brush
• Vacuum nozzle
•Salt Solution 75%
DI.SALT.75
RELATIVE
HUMIDITY
Meter Kit
SeeDelmhorst inactionat